Operating Room Temperature And Humidity

Each operating room should have separate temperature control.
Operating room temperature and humidity. Do i need to close the or if the temperature or humidity are out of range. Currently ashrae ashe standard 170 2017 ventilation of health care facilities defines the minimum relative humidity rh level for an operating room as 20 and the maximum level as 60. Percent or less as excessive humidity is conducive to microbial growth and compromises the integrity of wrapped sterile instruments and supplies. Temperature humidity and airflow in the operating rooms must be maintained within acceptable standards to inhibit bacterial growth and prevent infection and promote patient comfort.
To acutely decrease the rh level of an operating room one can either remove water vapor or increase temperature it is unlikely that one would increase the atmospheric pressure. The design requirements for these parameters in healhtcare settings are defined by ashrae standard 170 and are generally straightforward however or operating room users often try to operate or hvac heating ventilating and air conditioning systems at temperatures and humidity levels. Humidity and temperature from a single or over 2 months. Many supplies can be used outside of the minimum humidity requirements but should not be stored for long periods in low humidity conditions.
Health care facilities should consider the effects on equipment and or supplies before reducing operating room relative humidity below 30 percent. Regarding establishing humidity levels in the or per hdo protocols. The maintenance of the required level of relative humidity rh in the operating room or has been essential to control the growth of microorganisms prevent electrostatic discharge esd and comfort of the or team. Share this advisory with your chief operating.
Cold operating rooms have a higher rh than do warm operating rooms with the same absolute humidity figure 1. What are the recommended humidity ranges for an operating room. Access to this content requires a subscription. Organizations should determine the appropriate temperature and humidity and ventilation parameters based on the design criteria at the time of construction see also the note in ec 02 05 01 ep 15 for new renovated or altered spaces organizations that use the joint commission for deemed status purposes must use ashrae 170 2008 as.
Excessive humidity in the operating room is conducive to bacterial growth and compromises the integrity of wrapped sterile instruments and supplies. For example if a room is 68 f with 60 relative humidity within parameter range and you drop the temperature to 64 f the relative humidity will rise to 68 out of parameter range. While published guidelines are applicable to all.